6,655 research outputs found

    Genome scan of Diabrotica virgifera virgifera for genetic variation associated with crop rotation tolerance

    Get PDF
    Crop rotation has been a valuable technique for control of Diabrotica virgifera virgifera for almost a century. However, during the last two decades, crop rotation has ceased to be effective in an expanding area of the US corn belt. This failure appears to be due to a change in the insect's oviposition behaviour, which, in all probability, has an underlying genetic basis. A preliminary genome scan using 253 amplified fragment-length polymorphism (AFLP) markers sought to identify genetic variation associated with the circumvention of crop rotation. Samples of D. v. virgifera from east-central Illinois, where crop rotation is ineffective, were compared with samples from Iowa at locations that the behavioural variant has yet to reach. A single AFLP marker showed signs of having been influenced by selection for the circumvention of crop rotation. However, this marker was not diagnostic. The lack of markers strongly associated with the trait may be due to an insufficient density of marker coverage throughout the genome. A weak but significant general heterogeneity was observed between the Illinois and Iowa samples at microsatellite loci and AFLP markers. This has not been detected in previous population genetic studies of D. v. virgifera and may indicate a reduction in gene flow between variant and wild-type beetles

    Progressive multifocal leukoencephalopathy: Serial high-b-value diffusion-weighted MR imaging and apparent diffusion coefficient measurements to assess response to highly active antiretroviral therapy

    Get PDF
    A patient with human immunodeficiency virus-related posterior fossa progressive multifocal leukoencephalopathy had serial diffusion-weighted imaging using b-values of 1000 and 3000 before and during highly active antiretroviral therapy (HAART). High-b-value images provided a superior definition of the leading edge of the lesion and additional information about the integrity of white matter tracts. Following HAART, there was a marked reduction of lesional apparent diffusion coefficient and reconstitution of anisotropy in the affected middle cerebellar peduncle

    The effect of agitation speed, enzyme loading and substrate concentration on enzymatic hydrolysis of cellulose from brewer’s spent grain

    Get PDF
    Brewer’s spent grain components (cellulose, hemicellulose and lignin) were fractionated in a two-step chemical pretreatment process using dilute sulfuric acid and sodium hydroxide solutions. The cellulose pulp produced was hydrolyzed with a cellulolytic complex, Celluclast 1.5 L, at 45 ºC to convert the cellulose into glucose. Several conditions were examined: agitation speed (100, 150 and 200 rpm), enzyme loading (5, 25 and 45 FPU/g substrate), and substrate concentration (2, 5 and 8% w/v), according to a 2 3 full factorial design aiming to maximize the glucose yield. The obtained results were interpreted by analysis of variance and response surface methodology. The optimal conditions for enzymatic hydrolysis of brewer’s spent grain were identified as 100 rpm, 45 FPU/g and 2% w/v substrate. Under these conditions, a glucose yield of 93.1% and a cellulose conversion (into glucose and cellobiose) of 99.4% was achieved. The easiness of glucose release from BSG makes this substrate a raw material with great potential to be used in bioconversion processes.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Fundação de Amparo à Pesquisa do Estado de São Paulo), Brazil. Novozymes ( FAPESP )Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq

    Dependency-aware Attention Control for Unconstrained Face Recognition with Image Sets

    Full text link
    This paper targets the problem of image set-based face verification and identification. Unlike traditional single media (an image or video) setting, we encounter a set of heterogeneous contents containing orderless images and videos. The importance of each image is usually considered either equal or based on their independent quality assessment. How to model the relationship of orderless images within a set remains a challenge. We address this problem by formulating it as a Markov Decision Process (MDP) in the latent space. Specifically, we first present a dependency-aware attention control (DAC) network, which resorts to actor-critic reinforcement learning for sequential attention decision of each image embedding to fully exploit the rich correlation cues among the unordered images. Moreover, we introduce its sample-efficient variant with off-policy experience replay to speed up the learning process. The pose-guided representation scheme can further boost the performance at the extremes of the pose variation.Comment: Fixed the unreadable code in CVF version. arXiv admin note: text overlap with arXiv:1707.00130 by other author

    Dissipative effects on quantum glassy systems

    Full text link
    We discuss the behavior of a quantum glassy system coupled to a bath of quantum oscillators. We show that the system localizes in the absence of interactions when coupled to a subOhmic bath. When interactions are switched on localization disappears and the system undergoes a phase transition towards a glassy phase. We show that the position of the critical line separating the disordered and the ordered phases strongly depends on the coupling to the bath. For a given type of bath, the ordered glassy phase is favored by a stronger coupling. Ohmic, subOhmic and superOhmic baths lead to different transition lines. We draw our conclusions from the analysis of the partition function using the replicated imaginary-time formalism and from the study of the real-time dynamics of the coupled system using the Schwinger-Keldysh closed time-path formalism.Comment: 39 pages, 13 figures, RevTe

    A Case of Pseudomembranous Colitis after Voriconazole Therapy

    Get PDF
    This is a case report on a 35-year-old man with acute myelogenous leukemia who presented fever and intermittent mucoid loose stool to the emergency center. He had been taking voriconazole for invasive pulmonary aspergillosis. The flexible sigmoidoscopy was consistent with the diagnosis of pseudomembranous colitis

    Improving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope™ with a novel modification

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The Bonfils intubating fiberscope has a limited upward tip angle of 40° and requires retromolar entry into the hypopharynx. These factors may make its use less desirable when managing the difficult airway because most anesthesia providers are well versed in midline oral intubation rather than the lateral retromolar approach. The <it>Center for Advanced Technology and Telemedicine </it>at the University of Nebraska Medical Center has developed a novel fiberscope with a more anterior 60° curve to allow for easier midline insertion and intubation. The objective of this work was to evaluate the novel fiberscope, in comparison to the Bonfils intubating fiberscope, in terms of use and function in difficult airway intubation.</p> <p>Methods</p> <p>Twenty-two anesthesia providers participated in simulated intubations of a difficult airway mannequin to compare the Bonfils intubating fiberscope with the novel curved Boedeker intubating fiberscope. The intubations were assessed based upon the following variables: recorded Cormack Lehane airway scores, requests for cricoid pressure, time to intubation, number of intubation attempts and success or failure of the procedure.</p> <p>Results</p> <p>Participants using the Bonfils fiberscope recorded an average Cormack Lehane (CL) airway score of 1.67 ± 1.02 (median = 1); with the novel fiberscope, the recorded average airway grade improved to 1.18 ± 0.50 (median = 1). The difference in airway scores was not statistically significant (p = 0.34; Fishers Exact Test comparing CL grades 1&2 vs. 3&4). There was, however, a statistically significant difference in intubation success rates between the two devices. With the Bonfils fiberscope, 68% (15/22) of participants were successful in intubation compared to a 100% success rate in intubation with the novel fiberscope (22/22) (p = 0.008). After the intubation trial, the majority of participants (95%) indicated a preference for the novel fiberscope (n = 20).</p> <p>Conclusions</p> <p>With this data, we can infer that the novel fiberscope curvature appears to improve or maintain the quality of an intubation attempt (airway score, cricoid pressure requirement, intubation time, number of attempts, placement success). The data indicate that the novel fiberscope offers a superior intubation experience to currently available best practices. The instrument was well received and would be welcomed by most study participants should the device become clinically available in the future.</p
    corecore